THE SMART TRICK OF DP50RB THAT NO ONE IS DISCUSSING

The smart Trick of Dp50rb That No One is Discussing

The smart Trick of Dp50rb That No One is Discussing

Blog Article

The consumer is not really permitted to open up the covers and panel from the technique, neither Observe: system disassemble is permitted. To make sure the process functionality and security, only Mindray engineers or engineers approved by Mindray can perform upkeep.

The DP-fifty Skilled can be an modern, significant-overall performance Ultrasound Technique engineered to assist you receive the insights you require. The Program’s powerful engine and high-speed processing deliver excellent picture top quality and a whole facts administration Remedy.

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi detail mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

NOTE: Be certain that you could potentially pull out and force to the IO board sockets vertically when pulling out and assembling the IO board assembly around the position from the manage. Get rid of panhead screws with washers M3X6 (four) used to secure the IO board, after which you could potentially acquire out the IO board. Web page 116 Take away panhead screws with washers (two M3X6) which can be fixed on the leading device, consider out the higher baffle and afterwards pull out two cables connecting the main board to the ability module assembly.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

3. Simply click the upper icon inside the screen (prompts “Update” if you place the cursor on it), the update move is completed, if fails, remember to send to R&D Centre. Figure six-1 Most important Keep an eye on Maintenance Monitor four. Right after update is thriving, restart the device soon after power off to create the data powerful. HDD Partition ... Page 91 structured report relevant knowledge file and DICOM viewing software program Report report template obd.bin OBD facts file version.txt Variation file Remark Remark file AnatomyImage Anatomical illustrations or photos Measurement Measurement library Doppler program and similar boot configuration main file and plug-ins, distant desktop server Multilanguage string file exe videoplay.

Functionality Take a look at 5.5.1 Take a look at Method Resolution Detection depth Geometric Position Precision Blackout region examination History the exam photos five.5.2 Examination Written content The image utilised here is only for reference, stay with the image impact in the true Observe: problem. Specifications: Screen: set the distinction and brightness within the clinical software price (or the default status) Procedure surroundings: dark room, simulating the scientific application surroundings. Website page 76 In condition which the transverse resolution testing targets are horizontally exhibited, document the minimal length of two targets which can be clearly regarded. Repeat the operation higher than to the transverse resolution testing targets at other depths. As demonstrated in determine under. Axial resolution ... Webpage seventy seven When using the convex probe, retain the transverse resolution testing targets to NOTE: be exhibited near the midline. When employing a linear probe with steer operate, don't turn on the steer purpose when carry out the transverse resolution take a look at. Zoom while in the location exactly where the targets Situated if vital. The diameter in the focus on issue at a specific depth is equivalent to the transverse resolution with the depth. Site 78 5.

five.two.3 Geometric positioning precision Longitudinal geometric positioning precision  Take a look at Action: Do changes as just how in tests the most depth. Document the space by 20mm each phase around the longitudinal targets line utilizing the measurement caliper; Choose the worth with the best mistake (to 20mm), compute the accuracy utilizing the system beneath The measurement caliper really should be positioned with the higher fringe of the goal, NOTE:... Site 79 Transverse geometric positioning accuracy  Take a look at Stage: Deal with the scan surface area of the phantom with h2o or couple gel, gently Get in touch with the probe with the scan surface Change the depth, creating the transverse targets being displayed while in the impression. Change the focus position to be posited beside the transverse targets (the regular isn't obvious) Change parameters like gain, TGC, producing each transverse targets to become clearly displayed. Web page eighty five.5.two.four Blackout Spot Examination Phase: Deal with the scan floor on the phantom with drinking water or couple gel, Carefully Call the probe Using the scan area Regulate the depth at a reduce benefit, and set the main target at the nearest destination to the scan floor. Reduce the worth of parameters like AP, Acquire right until the background sounds just is often observed. Page 81: Software program Up grade And Maintenance

Take note: Before uploading the log, make certain the ultrasound method is connected to community, normally, the program could Dp50rb login alert “could not connect to server” The server (smtp.

Support 4D probe; figure out the probe via the ID code; change the 4D push signal by using the  electrical relay to make the 4D probe function normally. 4.two.2 Most important board The key board can be divided into two pieces: front-close of the leading board and again-end of the main board.

Return towards the system preset interface. The option status adjustments into Uninstalled. The uninstalling purpose is special to interior users.

This manual might referring to details guarded by copyright or patents and does not Express any license under the patent rights or copyright of Mindray, or of Other individuals. Webpage nine: Statement

A smart new form, Improved mobility and convenient operation make DP-50 well suited for all medical options.

Take note: On the observe, the brightness adjustment comes prior to contrast. Following readjusting the check’s contrast and brightness, adjust all preset and peripheral configurations.

Report this page